📄️ BACnet Device Explorer
Users can see every device that the DC620 DUAL BACnet IoT Gateway can communicate with in this menu. The current tabs allow switching views between MSTP1, MSTP2, and Who Is - I Am. If the target device supports read property in the object list property of the device object and read property multiple all in all its objects, readings can be made from this menu.
📄️ BACnet Network Explorer
In this menu, basic monitoring of BACnet networks can be performed. The other networks connected to the DC620 DUAL BACnet IoT Gateway and their router addresses can be viewed here. Some network layer messages can also be sent from here to diagnose and control the network. The view can be changed between the different ports of the DC620 DUAL BACnet IoT Gateway among the tabs:
📄️ BACnet Device Settings
Here, the BACnet settings of the device can be configured.
📄️ BACnet MSTP Settings
Here, the device's MS/TP settings can be configured. Tab 1 is for MSTP 1 (RS485 1); tab 2 is for MSTP 2 (RS485 2). Configuration Settings are divided into two sections: Network Settings and Port Settings. Network Settings are used for MS/TP network configurations; Port Settings are used for MS/TP timing configurations. Each settings group has its own Save Settings and Restore Defaults buttons. These buttons update the configurations for both MSTP 1 and MSTP 2.
📄️ BACnet IP Settings
Here, the device's BACnet/IP settings can be configured. Tab 1 is for B/IP 1 (Ethernet); tab 2 is for B/IP 2 (Wi-Fi). Configuration Settings is used for B/IP network configurations. The Save Settings and Restore Defaults buttons update the configurations for both B/IP 1 and B/IP 2.
📄️ BBMD
If a B/IP port is to be used as BBMD or FD, subscriptions and table records are managed from here. If a B/IP port is to be used as a foreign device, the BBMD to be subscribed can be entered from Foreign Device Settings. If the port is to be used as BBMD, other BBMDs and FDs can be viewed and managed from the Broadcast Distribution Table and Foreign Device Table.
📄️ BACnet Virtual Devices
Virtual BACnet Devices are managed from this menu. To activate these devices, Working Mode and Port must be entered. For a virtual device to operate, the working mode of the corresponding port of the real device must match the working mode of the virtual device. A maximum of 20 BACnet Virtual Devices can be present.
📄️ COV
The list of BACnet COV subscribers and information about subscriptions is displayed here. The maximum supported number of subscribers is 100. Only 3 subscriptions can be made per existing object.
📄️ BACnet Statistics
MSTP 1, MSTP 2, BACnet IP 1, BACnet IP 2 port statistics are displayed here.