SensNode METEO-MB-10
| Messparameter | Messbereich | Messgenauigkeit | Auflösung |
|---|---|---|---|
| Lufttemperatur | -40 — 85 °C | ±0.1 °C | 0.01 °C |
| Feuchtigkeit | 0 — 100 %RH | ±1.5 %RH | 0.01 %RH |
| Barometrischer Druck | 300 — 1250 hPa | ±50 Pa | 10 Pa |
| Windgeschwindigkeit | 0 — 60 m/s | ±0.3 m/s (≤ 10 m/s) ±3% (10 m/s — 50 m/s) | 0.1 m/s |
| Windrichtung | 0 — 360° (-40 — 60 °C) | ±3.0° | 0.1° |
| Lichtintensität | 0 — 188000 Lux | %5 | 5 Lux |
| Regensensor | 0 — 200 mm/h | ±%10 | 0.2 mm / 0.02 mm |
| PM2.5 | 0 — 1000 μg/㎥ | ±10 μg/㎥ (0 μg/㎥ — 100 μg/㎥) ±10% (100 μg/㎥ — 1000 μg/㎥) | 1 μg/㎥ |
| PM10 | 0 — 1000μg/㎥ | ±15 μg/㎥ (0 μg/㎥ — 100 μg/㎥) ±15% (100 μg/㎥ — 1000 μg/㎥) | 1 μg/㎥ |
| CO2 | 400 — 5000 ppm | ±(30 ppm + 3% ppm) | 1 ppm |